Polycap TC (PES) is available with and without a filling bell, theyare disposable, dual layer polyethersulfone (PES) membrane filtration capsules that provide efficient filtration for critical aqueous solutions.

 
The PES membrane is inherently hydrophilic, has low extractables, is bio-safe, has excellent flow rates and exhibits low protein binding.
 
 
 
Features and Benefits
  • Polycap TC/PES 0.2/0.1, 0.2/0.2 and 0.8/0.2 µm capsules pass the HIMA Challenge Test for Sterilizing Grade Filters
  • 100% integrity-tested during manufacturing; results are correlated to microbial retention
  • Housing thermally fused (no surfactants or mold releasing agents)
  • Integrity-testable by bubble point, pressure decay or forward flow methods
  • Available in sterile and non-sterile versions with a filling bell option
  • Manufactured in clean room facilities under ISO Quality Systems
  • PES membrane protein adsorption characteristics:
    HSA 0.4 µg/cm2
    Insulin 2.0 µg/cm2
    Gammaglobulin 1.5 µg/cm2

     

Applications
  • Aqueous solutions
  • Biologicals
  • Buffers
  • Cleaning/rinsing solutions
  • Enzymes
  • High-quality water
  • Particle counting solutions
  • Pharmaceutical solutions
  • Reagent preparation
  • Salt solutions
  • Tissue culture media
  • Virus suspensions






 
Technical Properties - Polycap TC 
Housing Polypropylene 
Vent On inlet 
Membrane Polyethersulfone (PES) 
Support System Polypropylene 
Sealing Heat-fused 
Maximum Pressure 60 psi (4.1 bar)
Flow Direction If there is a prefilter, it is located on the inlet side and flow should follow arrows
Endotoxin Level LAL tested, ≤  0.5 EU/mL 
Biosafety Materials pass USP Class VI 
Sterilization Certain filter devices have been sterilized.* Capsule may be autoclaved at 121° C for 20 minutes (maximum 132° C). However, an integrity test should be performed after autoclaving. (*sterile and non-sterile options offered)
Filtration Area 36 mm capsule: 440 cm2 (72 in2)
75 mm capsule: 930 cm2 (144 in2)
150 mm capsule: 1,900 cm2 (302 in2
Water Bubble Point (Final Membrane) 0.1 µm > 3.2 bar (46 psi) 
0.2 µm > 2.7 bar (40 psi) 
0.45 µm > 2.1 bar (30 psi)
1.0 µm > 1.1 bar (16 psi)
 

SB - Stepped Barb for 6-10 mm (1/4"-3/8") tubing
1/2 SB - Stepped Barb for 10-12 mm (3/8"-1/2") tubing
MNPT - Male National Pipe Thread
HB - Hose Barb

 


Ordering Information - Polycap TC
Catalog Number Description
6714-3601 Polycap TC 36, 0.2/0.1µm Sterile with SB inlet and outlet 1/pk
6714-3602 Polycap TC 36, 0.2/0.2µm Sterile with SB inlet and outelt 1/pk
6717-3602 Polycap TC 36, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet 1/pk
2622NS Polycap TC 36, 0.2/0.2µm with HB inlet and SB outlet 5/pk
6714-3604 Polycap TC 36, 0.65/0.45µm Sterile with SB inlet and outelt 1/pk
6715-3601 Polycap TC 36, 0.2/0.1µm Sterile with SB inlet and outlet plus filling bell 1/pk
6715-3602 Polycap TC 36, 0.2/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk
6716-3612 Polycap TC 36, 0.2/0.2µm with 1/2 SB inlet and SB outlet plus filling bell 1/pk
6716-3602 Polycap TC 36, 0.2/0.2µm with MNPT inlet and SB outlet plus filling bell 1/pk
6715-3604 Polycap TC 36, 0.65/0.45µm Sterile with SB inlet and outlet plus filling bell 1/pk
6715-3682 Polycap TC 36, 0.8/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk
6714-7501 Polycap TC 75, 0.2/0.1µm Sterile with SB inlet and outlet 1/pk
6714-7502 Polycap TC 75, 0.2/0.2µm Sterile with SB inlet and outlet 1/pk
2742C Polycap TC 75, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet 5/pk
2742M Polycap TC 75, 0.2µm with MNPT inlet and outlet 5/pk
6717-7504 Polycap TC 75, 0.65/0.45µm Sterile with 1/2 SB inlet and outlet 1/pk
6714-7504 Polycap TC 75, 0.65/0.45µm Sterile with SB inlet and outlet 1/pk
6717-7510 Polycap TC 75, 1.0/1.0µm Sterile with 1/2 SB inlet and outlet 1/pk
6715-7501 Polycap TC 75, 0.2/0.1µm Sterile with SB inlet and outlet plus filling bell 1/pk
6715-7502 Polycap TC 75, 0.2/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk
6716-7502 Polycap TC 75, 0.2/0.2 µm Sterile with MNPT inlet and SB outlet plus filling bell 1/pk
6718-7504 Polycap TC 75, 0.65/0.45µm with 1/2 SB inlet and SB outlet plus filling bell 1/pk
6715-7582 Polycap TC 75, 0.8/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk
6717-9501 Polycap TC 150, 0.2/0.1µm Sterile with 1/2 SB inlet and outlet 1/pk
6717-9502 Polycap TC 150, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet 1/pk
6704-9502 Polycap TC 150, 0.2/0.2µm with 1 1/2" Sanitary inlet and outlet 1/pk
6717-9504 Polycap TC 150, 0.65/0.45µm Sterile with 1/2 SB inlet and outlet 1/pk
6717-9510 Polycap TC 150, 1.0/1.0µm Sterile with 1/2 SB inlet and outlet 1/pk
6718-9502 Polycap TC 150, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet plus filling bell 1/pk
6718-9582 Polycap TC 150, 0.8/0.2µm Sterile with 1/2 SB inlet and outlet plus filling bell 1/pk

Supporting Documentation - Polycap TC
Document Name
Polycap TC Datasheet
Support Documentation
Ordering Information
Contact Us
Printable Version