Polycap TC
|
|
Home | Filtration Devices | Capsule Filters | Polycap TC
|
|
Polycap TC (PES) is available with and without a filling bell, theyare disposable, dual layer polyethersulfone (PES) membrane filtration capsules that provide efficient filtration for critical aqueous solutions.
|
 |
| |
| The PES membrane is inherently hydrophilic, has low extractables, is bio-safe, has excellent flow rates and exhibits low protein binding. |
| |
| |
| |
Features and Benefits
- Polycap TC/PES 0.2/0.1, 0.2/0.2 and 0.8/0.2 µm capsules pass the HIMA Challenge Test for Sterilizing Grade Filters
- 100% integrity-tested during manufacturing; results are correlated to microbial retention
- Housing thermally fused (no surfactants or mold releasing agents)
- Integrity-testable by bubble point, pressure decay or forward flow methods
- Available in sterile and non-sterile versions with a filling bell option
- Manufactured in clean room facilities under ISO Quality Systems
- PES membrane protein adsorption characteristics:
HSA 0.4 µg/cm2
Insulin 2.0 µg/cm2
Gammaglobulin 1.5 µg/cm2
Applications
- Aqueous solutions
- Biologicals
- Buffers
- Cleaning/rinsing solutions
- Enzymes
- High-quality water
- Particle counting solutions
- Pharmaceutical solutions
- Reagent preparation
- Salt solutions
- Tissue culture media
- Virus suspensions
|


 |
| |
|
| Technical Properties - Polycap TC |
| Housing |
Polypropylene |
| Vent |
On inlet |
| Membrane |
Polyethersulfone (PES) |
| Support System |
Polypropylene |
| Sealing |
Heat-fused |
| Maximum Pressure |
60 psi (4.1 bar) |
| Flow Direction |
If there is a prefilter, it is located on the inlet side and flow should follow arrows |
| Endotoxin Level |
LAL tested, ≤ 0.5 EU/mL |
| Biosafety |
Materials pass USP Class VI |
| Sterilization |
Certain filter devices have been sterilized.* Capsule may be autoclaved at 121° C for 20 minutes (maximum 132° C). However, an integrity test should be performed after autoclaving. (*sterile and non-sterile options offered) |
| Filtration Area |
36 mm capsule: 440 cm2 (72 in2)
75 mm capsule: 930 cm2 (144 in2)
150 mm capsule: 1,900 cm2 (302 in2) |
| Water Bubble Point (Final Membrane) |
0.1 µm > 3.2 bar (46 psi)
0.2 µm > 2.7 bar (40 psi)
0.45 µm > 2.1 bar (30 psi)
1.0 µm > 1.1 bar (16 psi) |
|
SB - Stepped Barb for 6-10 mm (1/4"-3/8") tubing
1/2 SB - Stepped Barb for 10-12 mm (3/8"-1/2") tubing
MNPT - Male National Pipe Thread
HB - Hose Barb
|
| Ordering Information - Polycap TC |
| Catalog Number |
Description |
| 6714-3601 |
Polycap TC 36, 0.2/0.1µm Sterile with SB inlet and outlet 1/pk |
| 6714-3602 |
Polycap TC 36, 0.2/0.2µm Sterile with SB inlet and outelt 1/pk |
| 6717-3602 |
Polycap TC 36, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 2622NS |
Polycap TC 36, 0.2/0.2µm with HB inlet and SB outlet 5/pk |
| 6714-3604 |
Polycap TC 36, 0.65/0.45µm Sterile with SB inlet and outelt 1/pk |
| 6715-3601 |
Polycap TC 36, 0.2/0.1µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6715-3602 |
Polycap TC 36, 0.2/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6716-3612 |
Polycap TC 36, 0.2/0.2µm with 1/2 SB inlet and SB outlet plus filling bell 1/pk |
| 6716-3602 |
Polycap TC 36, 0.2/0.2µm with MNPT inlet and SB outlet plus filling bell 1/pk |
| 6715-3604 |
Polycap TC 36, 0.65/0.45µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6715-3682 |
Polycap TC 36, 0.8/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6714-7501 |
Polycap TC 75, 0.2/0.1µm Sterile with SB inlet and outlet 1/pk |
| 6714-7502 |
Polycap TC 75, 0.2/0.2µm Sterile with SB inlet and outlet 1/pk |
| 2742C |
Polycap TC 75, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet 5/pk |
| 2742M |
Polycap TC 75, 0.2µm with MNPT inlet and outlet 5/pk |
| 6717-7504 |
Polycap TC 75, 0.65/0.45µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 6714-7504 |
Polycap TC 75, 0.65/0.45µm Sterile with SB inlet and outlet 1/pk |
| 6717-7510 |
Polycap TC 75, 1.0/1.0µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 6715-7501 |
Polycap TC 75, 0.2/0.1µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6715-7502 |
Polycap TC 75, 0.2/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6716-7502 |
Polycap TC 75, 0.2/0.2 µm Sterile with MNPT inlet and SB outlet plus filling bell 1/pk |
| 6718-7504 |
Polycap TC 75, 0.65/0.45µm with 1/2 SB inlet and SB outlet plus filling bell 1/pk |
| 6715-7582 |
Polycap TC 75, 0.8/0.2µm Sterile with SB inlet and outlet plus filling bell 1/pk |
| 6717-9501 |
Polycap TC 150, 0.2/0.1µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 6717-9502 |
Polycap TC 150, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 6704-9502 |
Polycap TC 150, 0.2/0.2µm with 1 1/2" Sanitary inlet and outlet 1/pk |
| 6717-9504 |
Polycap TC 150, 0.65/0.45µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 6717-9510 |
Polycap TC 150, 1.0/1.0µm Sterile with 1/2 SB inlet and outlet 1/pk |
| 6718-9502 |
Polycap TC 150, 0.2/0.2µm Sterile with 1/2 SB inlet and outlet plus filling bell 1/pk |
| 6718-9582 |
Polycap TC 150, 0.8/0.2µm Sterile with 1/2 SB inlet and outlet plus filling bell 1/pk |
|
|
|