GD/X® Syringe Filters
|
|
Home | Filtration Devices | Syringe Filters | GD/X® Syringe Filters
|
|
The GD/X® range is specifically designed for high particulate loaded samples. Constructed of a pigment-free polypropylene housing with a prefiltration stack of Whatman GMF 150 (graded density) and GF/F glass microfiber media, these filters eliminate sample contamination and allow you to filter even the most difficult samples with less hand pressure. GD/X syringe filters can process three to seven times more sample volume than unprotected membranes.
|

25 mm GD/X
|
|
|
| |
| GMF 150 and GF/F are produced from 100% borosilicate glass microfiber. The unique, graded density GMF 150 medium has a coarse top layer meshed with a fine bottom layer that retains particles to 1.0 µm. A GF/F filter then retains particles down to 0.7 µm. The prefilter stack ends with a final membrane. |
| |
| GD/X filter construction facilitates exceptional loading capacity with fast flow rates. This prevents the build up of back pressure typically caused by the blocking of an unprotected membrane. |
| |
Features:
- 13 mm and 25 mm diameter syringe filters
- 13 mm devices for samples up to 10 mL and 25 mm devices for samples greater than 10 mL (however, the volume of sample that can be filtered through each filter depends on the characteristics of the sample)
- Sterile options
- Pigment-free polypropylene housing
- Unique prefiltration stack of Whatman GMF 150 (graded density) and GF/F glass microfiber media
Benefits:
- Eliminates sample contamination
- Requires less hand pressure, even with the most
difficult samples
- Processes three to seven times more sample volume
Applications
GD/X syringe filters are ideal for heavily particulate-laden samples found in:
- Dissolution testing
- Content uniformity
- Concentration analysis
- Routine sample preparation
- Food analysis
- Environmental samples
- Composite assay
|
|
| Typical Data - GD/X Syringe Filters |
| |
GD/X 13 mm
|
GD/X 25 mm
|
|
Housing
|
Polypropylene (pigment free)
|
Polypropylene (pigment free)
|
|
Filtration Area
|
1.3 cm2
|
4.6 cm2
|
|
Maximum Pressure
|
100 psi (6.9 bar)
|
75 psi (5.2 bar)
|
|
Volume 'Hold Up' - Full housing
- with air purge
|
0.5 mL
50 µL (approx)
|
1.4 mL
250 µL (approx)
|
|
Dimensions
|
21.6 mm x 29.8 mm
|
20.8 mm x 29.8 mm
|
|
Weight
|
3 g (approx)
|
3 g (approx)
|
|
Flow Direction
|
Flow should enter from the inlet
|
Flow should enter from the inlet
|
|
Inlet Connection
|
Female luer lock
|
Female luer lock
|
|
Outlet Connection
|
Male luer
|
Male luer
|
|
Sterlization
|
Autoclave at 121º C (131º C max) at 15 psi (1 bar) for 20 minutes
|
Autoclave at 121º C (131º C max) at 15 psi (1 bar) for 20 minutes
|
|
Biosafe
|
All materials pass USP Class VI
|
All materials pass USP Class VI
|
|
Glass Microfiber Prefiltration Media
|
100% Borosilicate Glass Fiber
GMF 150 10 µm: 1 µm
GF/F 0.7 µm
|
100% Borosilicate Glass Fiber
GMF 150 10 µm: 1 µm
GF/F 0.7 µm
|
|
| Ordering Information - GD/X® Syringe Filters |
| Catalog Number |
Description |
13 mm GD/X - Non-Sterile
Nylon Filtration Media |
|
| 6870-1302 |
GD/X 13 Syringe Filter, Nylon, 0.2 µm 150/pk |
| 6871-1302 |
GD/X 13 Syringe Filter, Nylon, 0.2 µm 1500/pk |
| 6870-1304 |
GD/X 13 Syringe Filter, Nylon, 0.45 µm 150/pk |
| 6871-1304 |
GD/X 13 Syringe Filter, Nylon, 0.45 µm 1500/pk |
|
| 6872-1302 |
GD/X 13 Syringe Filter, PVDF, 0.2 µm 150/pk |
| 6872-1304 |
GD/X 13 Syringe Filter, PVDF, 0.45 µm 150/pk |
| 6873-1304 |
GD/X 13 Syringe Filter, PVDF, 0.45 µm 1500pk |
|
| 6874-1302 |
GD/X 13 Syringe Filter, PTFE, 0.2 µm 150/pk |
| 6875-1302 |
GD/X 13 Syringe Filter, PTFE, 0.2 µm 1500/pk |
| 6874-1304 |
GD/X 13 Syringe Filter, PTFE, 0.45 µm 150/pk |
| 6875-1304 |
GD/X 13 Syringe Filter, PTFE, 0.45 µm 1500pk |
|
| 6876-1302 |
GD/X 13 Syringe Filter, PES, 0.2 µm 150/pk |
| 6876-1304 |
GD/X 13 Syringe Filter, PES, 0.45 µm 150/pk |
|
| 6878-1302 |
GD/X 13 Syringe Filter, PP, 0.2 µm 150/pk |
| Cellulose Acetate Filtration Media |
|
| 6880-1302 |
GD/X 13 Syringe Filter, CA, 0.2 µm 150/pk |
| 6880-1304 |
GD/X 13 Syringe Filter, CA, 0.45 µm 150/pk |
| Glass Microfiber Filtration Media |
|
| 6894-1304 |
GD/X 13 Syringe Filter, GMF, 0.45 µm 150/pk |
| 6882-1316 |
GD/X 13 Syringe Filter, GF/A, 1.6 µm 150/pk |
| 6884-1310 |
GD/X 13 Syringe Filter, GF/B, 1.0 µm 150/pk |
| 6886-1312 |
GD/X 13 Syringe Filter, GF/C, 1.2 µm 150/pk |
| 6888-1327 |
GD/X 13 Syringe Filter, GF/D, 2.7 µm 150/pk |
| 6890-1307 |
GD/X 13 Syringe Filter, GF/F, 0.7 µm 150/pk |
25 mm GD/X - Non-Sterile
Nylon Filtration Media |
|
| 6869-2502 |
GD/X 25 Syringe Filter, Nylon High Charge (positive), 0.2 µm 150/pk |
| 6869-2504 |
GD/X 25 Syringe Filter, Nylon High Charge (positive), 0.45 µm 150/pk |
| 6870-2502 |
GD/X 25 Syringe Filter, Nylon, 0.2 µm 150/pk |
| 6871-2502 |
GD/X 25 Syringe Filter, Nylon, 0.2 µm 1500/pk |
| 6870-2504 |
GD/X 25 Syringe Filter, Nylon, 0.45 µm 150/pk |
| 6871-2504 |
GD/X 25 Syringe Filter, Nylon, 0.45 µm 1500/pk |
| 6870-2550 |
GD/X 25 Syringe Filter, Nylon, 5.0 µm 150/pk |
| 6871-2550 |
GD/X 25 Syringe Filter, Nylon, 5.0 µm 1500/pk |
|
| 6872-2502 |
GD/X 25 Syringe Filter, PVDF, 0.2 µm 150/pk |
| 6873-2502 |
GD/X 25 Syringe Filter, PVDF, 0.2 µm 1500/pk |
| 6872-2504 |
GD/X 25 Syringe Filter, PVDF, 0.45 µm 150/pk |
| 6873-2504 |
GD/X 25 Syringe Filter, PVDF, 0.45 µm 1500pk |
|
| 6874-2502 |
GD/X 25 Syringe Filter, PTFE, 0.2 µm 150/pk |
| 6875-2502 |
GD/X 25 Syringe Filter, PTFE, 0.2 µm 1500/pk |
| 6874-2504 |
GD/X 25 Syringe Filter, PTFE, 0.45 µm 150/pk |
| 6875-2504 |
GD/X 25 Syringe Filter, PTFE, 0.45 µm 1500/pk |
|
| 6876-2502 |
GD/X 25 Syringe Filter, Polyethersulphone, 0.2 µm 150/pk |
| 6905-2502 |
GD/X 25 Syringe Filter, Polyethersulphone, 0.2 µm 1500/pk |
| 6876-2504 |
GD/X 25 Syringe Filter, Polyethersulphone, 0.45 µm 150/pk |
| 6905-2504 |
GD/X 25 Syringe Filter, Polyethersulphone, 0.45 µm 1500/pk |
|
| 6878-2502 |
GD/X 25 Syringe Filter, Polypropylene, 0.2 µm 150/pk |
| Cellulose Acetate Filtration Media |
|
| 6880-2502 |
GD/X 25 Syringe Filter, Cellulose Acetate, 0.2 µm 150/pk |
| 6881-2502 |
GD/X 25 Syringe Filter, Cellulose Acetate, 0.2 µm 1500/pk |
| 6880-2504 |
GD/X 25 Syringe Filter, Cellulose Acetate, 0.45 µm 150/pk |
| 6881-2504 |
GD/X 25 Syringe Filter, Cellulose Acetate, 0.45 µm 1500/pk |
| Glass Microfiber Filtration Media |
|
| 6894-2504 |
GD/X 25 Syringe Filter, Glass Microfibre, 0.45 µm 150/pk |
| 6895-2504 |
GD/X 25 Syringe Filter, Glass Microfibre, 0.45 µm 1500/pk |
| 6882-2516 |
GD/X 25 Syringe Filter, GF/A, 1.6 µm 150/pk |
| 6883-2516 |
GD/X 25 Syringe Filter, GF/A, 1.6 µm 1500/pk |
| 6884-2510 |
GD/X 25 Syringe Filter, GF/B, 1.0 µm 150/pk |
| 6886-2512 |
GD/X 25 Syringe Filter, GF/C, 1.2 µm 150/pk |
| 6888-2527 |
GD/X 25 Syringe Filter, GF/D, 2.7 µm 150/pk |
| 6890-2507 |
GD/X 25 Syringe Filter, GF/F, 0.7 µm 150/pk |
| 6891-2507 |
GD/X 25 Syringe Filter, GF/F, 0.7 µm 1500/pk |
| 6892-2515 |
GD/X 25 Syringe Filter, 934AH, 1.5 µm 150/pk |
25 mm GD/X - Sterile
PES Filtration Media |
|
| 6896-2502 |
GD/X 25 Syringe Filter, Sterile, PES, 0.2 µm 50/pk |
| 6896-2504 |
GD/X 25 Syringe Filter, Sterile, PES, 0.45 µm 50/pk |
| 6897-2502 |
GD/X 25 Syringe Filter, Sterile, PES, 0.2 µm 500/pk |
| 6897-2504 |
GD/X 25 Syringe Filter, Sterile, PES, 0.45 µm 500/pk |
|
| 6900-2502 |
GD/X 25 Syringe Filter, Sterile, PVDF, 0.2 µm 50/pk |
| 6900-2504 |
GD/X 25 Syringe Filter, Sterile, PVDF, 0.45 µm 50/pk |
| Cellulose Acetate Filtration Media |
|
| 6901-2502 |
GD/X 25 Syringe Filter, Sterile, Cellulose Acetate, 0.2 µm 50/pk |
| 6901-2504 |
GD/X 25 Syringe Filter, Sterile, Cellulose Acetate, 0.45 µm 50/pk |
| Glass Microfiber Filtration Media |
|
| 6902-2504 |
GD/X 25 Syringe Filter, Sterile, Glass Microfibre, 0.45 µm 50/pk |
|
|
|